AS 1530.3 Australia Standard Flame/Smoke Rating
CSIRO Testing Laboratory
-
- 11mm Plywood, Test Report # FNE 7715
- (0-20) Ignitability - 1
- (0-20) Spread of Flame - 0
- (0-10) Heat evolved - 0
- (0-10) Smoked Developed - 4
- 11mm Plywood, Test Report # FNE 7715
Flammability Standards (FAR Part 25) Section 25.853
Australian Wool Testing Authority Ltd
-
- Timber pallets
- Test Report # 7-513964-CN
- Timber pallets
AS 1530.4 Australia Standard
DEPARTMENT OF DEFENCE, SCIENCE AND TECHNOLOGY
-
- Polyester GRP composites
AS 1530.4 Australia Standard 30/30/30 Rating
CSIRO Testing Laboratory
-
- 20mm pine weatherboard at both sides of 90mm x 45mm, 2"x4" studs
- Test Report # FSV 0989
- 20mm pine weatherboard at both sides of 90mm x 45mm, 2"x4" studs
AS 1530.4 Australia Standard 60/60/60 Rating
CSIRO Testing Laboratory
-
- Timber horizontal test
- Assessment Number FC0 2638
- Timber horizontal test
AS 1530.4 Australia Standard 60/60/60 Rating Ceiling System
-
- Straw fiber cement panels
- Proprietary 3rd party fire test, Australian National University
- Straw fiber cement panels
AS 1530.4 Australia Standard 60/60/60 Rating
-
- 8mm Cement fiberboard panels
- Proprietary 3rd party fire test
- 8mm Cement fiberboard panels
AS 1530.4 Australia Standard 60/60/60 Rating
CSIRO Testing Laboratory
-
- 13mm non rated plasterboard
- Test Report # FSV 0653, Assessment Number FCO 1698
- 13mm non rated plasterboard
AS 1530.4 Australia Standard 60/60/60 Rating
CSIRO Testing Laboratory
-
- Pressed metal ceiling
- Assessment Number FCO 2278
- Pressed metal ceiling
AS 1530.4 Australia Standard 120/120/120 Rating
CSIRO Testing Laboratory
-
- Masonry walls
- Test Report # FSV 0653, Assessment Number FC0 2638
- Masonry walls
Third Party Testing
-
- 6 mm Fiber cardboard sculpture, 2000 microns tested to 15 min Room Fire Test
- Proprietary fire test, Sydney Harbor Restaurant
- Fiberglass/carbon fiber
- Bombardier business Learjet, 3rd party proprietary fire test by FAA
- 6 mm Fiber cardboard sculpture, 2000 microns tested to 15 min Room Fire Test
British Standard 476 Part 6 & 7
BRE Global Laboratories
-
- 12mm Timber Boards
- Test Report #s BRE 262682 and BRE 259490
- 12mm Timber Boards
ASTM E-119 – 30 minutes, positive pressure
Singapore Institute of Standards and Industrial Research (SISIR)
-
- 5/16" mahogany plywood panel (5) in solid wood (1 3/4") rails, 30 minutes positive pressure. (Singapore)
- Test Report # SISIR 96003
- 5/16" mahogany plywood panel (5) in solid wood (1 3/4") rails, 30 minutes positive pressure. (Singapore)
Firefree has conducted extensive testing on most substrates from the construction industry to a variety of fire retardant, fire resistant standards.
Please refer to:
Test Listings by Standard
- Fire Retardant Tests
- Fire Resistant Tests
- Other Tests
Test Listings by Substrate
Please refer to:
Test Listings by Standard
- Fire Retardant Tests
- Fire Resistant Tests
- Other Tests
Test Listings by Substrate