UBC 26-2, Thermal Barrier
- 7/16” Oriented Stand Board (OSB) exterior skin, polystyrene foam interior.
- Report: WFC 99070
UBC 26-3 Room Corner Test
- 5/8” CDX plywood
- Report FM 4880
- ½” AC Plywood
- Report FM 4880
- 5/8” Douglas fir; test resulted in no flame spread, smoke or room flashover.
- University of California, Forest Products Laboratories @ Berkeley.
- ½” Masonite board siding.
- University of California, Forest Products Laboratories @ Berkeley.
- Cedar shingles.
- University of California, Forest Products Laboratories @ Berkeley.
- ¼” Mahogany paneling.
- University of California, Forest Products Laboratories @ Berkeley.
- 7/16” Oriented Strand Board siding.
- University of California, Forest Products Laboratories @ Berkeley.
- 7/16” Lap siding.
- University of California, Forest Products Laboratories @ Berkeley.
UBC 7-2, Doors
- 1 3/8” non-rated solid core door, ASTM E-119, 45 minutes at negative pressure.
- Warnock Hersey Report No. WHI-495-1569
- 5/16” mahogany plywood panel (5) in solid wood (1 ¾”) rails, 30 minutes at positive pressure. (Singapore)
- SISIR Report No. 96003
FM 4975 Ceiling Test (Hydrocarbon)
- 1x4 Douglas Fir T&G
- Report No. FM 4975-3019443
ASTM E-84, Steiner Tunnel Test
- 1x4” Douglas Fir T&G
- Report No. Omega 15810-111045
- 7/16” Oriented Strand Board.
- Report No. UL 14654
ASTM E 119, 1 Hr Wall System
- 5/8” fire treated plywood each side of 6” metal studs.
- WFC evaluation letter. Meyer store # 222 project.
- ¾” T & G wood veneer over 5/8 gypsum, over wall studs.
- WFC evaluation letter. Nordic Log Homes project.
- (12.5mm) ½” T&G pine weatherboard at both sides of 90mm x 45mm (2”x4”) studs @ 450mm on center (16”o.c.).
- CSIRO, Report No. FSV 0989 (Australia Standard (1530-4).
- ½” Exterior plywood shear wall over 2x6 studs @ 16” o.c.
- WFC engineering letter. Plywood shear walls project. Seattle, WA.
- 7/16” timberline hardboard siding on stud wall.
- Report: WFC No. 01003
- ½” Oriented Stand Board (OSB) over 3x6 wood studs @ 16”o.c. with one layer, 5/8” type-X sheetrock @ opposite interior wall.
- WFC engineering letter. Student/Housing project
ASTM E 119, 1 Hr Ceiling System
- Exposed 2x6 T &G Pine with 3” Polyisocyanurate foam, 2x4 sleepers & ½” CDX Plywood sheathing.
- Report: WFC No. 99079 T2.
- Exposed full dimensional 2x10 joists @ 16”o.c. with 1 3/4” wood sub-floor with 3 ½” fiberglass insulation @ joists.
- WFC engineering letter. Mercy Gardens project.
- Exposed full dimensional 2x10 joists @ 16”o.c. with exposed 1¾” wood sub-floor
- WFC evaluation letter. Structural engineering calculations: Ron Loar, P.E.
- Women’s Facility Center project.
- 2x14 joists @ 16”o.c. with 2 layers. ¾” Plywood sub-floor with 3 ½” mineral wood insulation between joists with suspended sheetrock ceiling.
- WFC engineering letter. 37 & 39 South 1st Street project, San Jose, CA.
- 2x4 web trusses @ 24” o.c. with ¾” plywood roof sheathing with 3 ½” polyisocyanurate foam and roof membrane.
- WFC evaluation letter. Ruby’s Dinner project, Washington, DC.
- Assorted glue lam beams; 2 ¼” mini-lams; 2x10 joists and 5/8” OSB floor sheathing.
- Structural engineering calculations: Ron Loar, P.E. Avignon Apts project.
- Roof system, glue lams.
- Structural engineering calculations: Ron Loar, P.E. Abundant Life Church project, Mountain view, CA.
ASTM E 119, 2 Hr Ceiling System
- Exposed 3x10 joists @ 16”o.c. with 4 ¾” wood layered sub-floor.
- Report number WFC 00124 T1
ASTM E-1623, I-Cal
- Medium cedar shakes. WFC 98054
- 5/8” T-111 Douglas fir siding
- 5/8” AC plywood
- ½” OSB
- 1/4” mahogany paneling
GYPSUM BOARD
UBC 26-3 Room Corner Test
- ½” Type-X Gypsum and ½” AC Plywood
- Report No. WFC 04008
FM 4975 Ceiling Test
- ½” Gypsum board
- Report No. FM 4975
ASTM E-119, 1 Hr Wall System
- ½” sheetrock 2x4 wood studs @ 16” o.c.
- Report number WFC 00089 T1&T2
- ½” non-rated sheetrock over 1 ½” metal studs @ 16 oc. non-load bearing. Test performed at CSIRO, Australia
- CSIRO Report No. FSV0989
- 5/8” sheetrock 2x4 wood studs @ 16”o.c. (Gypsum lawsuit).
- Report number WFC 99064 T1.
- 5/8” gypsum board, 20, 40, 60 mils
- Report No. WFC 99055 T1.T2.T3
- 1 layer 5/8” sheetrock non-load bearing on 2x4 wood studs @16”o.c.
- WFC evaluation letter.
- 2 layers 5/8” sheetrock, loaded stud wall with 9 built in defects.
- Report: SIP No. 35.04.439 University of California, Forest Laboratory
ASTM E-119, 1 Hr Ceiling System
- 5/8” type-X sheetrock, single layer on 2x10 joists @ 16”o.c. with defective nailing, with 5/8” T &G Plywood sub-floor.
- Report: WFC No. 99053 3.T1
- 5/8” single layer 5/8” type-X sheetrock on 2x10 joists @ 24”o.c. with defective nailing with 5/8” T &G Plywood sub-floor.
- Report: WFC No. 99053 2.T3
- Single layer 5/8” type-X sheetrock over RC channel @ 24”o.c. with 2x8 joists @ 16”oc. with ¾” T&G Plywood sub-floor.
- Report: WFC No. 99067 T1.T2.T3.T4
- Single layer 5/8” type-X sheetrock over RC channel @ 24”o.c. with 9 ½”-250 series TJI @ 19.2”oc.
- Report: WHI-495-PSH-0245, Intertek Testing Services.
- Single layer 5/8” type-X sheetrock on BCI 450 series. I joists @ 16”o.c. with defective nailing.
- Report: WFC No. 00019 T3
ASTM E-119, 2 Hr Ceiling System
- Defective U.L assembly BXUV-G524 where ½” type-C was required & ½” non-rated was installed.
- WFC evaluation letter. Sagamore Towers project, Quincy, MA
- Single layer 5/8” type-X sheetrock with nominal 2x10 joists @ 16”o.c. with ¾” plywood sub-floor & ¾” gypcrete.
- WFC engineering letter. Residence Inn project.
ASTM E-1623, I-Cal
- 5/8” sheetrock
- WFC 98054
BSS-7239-88, Boeing Toxicity Test
- ½’ sheetrock
- Anderson Laboratories Report 497
LATH AND PLASTER
ASTM E 119, 1 Hr Wall System
- 1” thick plaster attached to metal wall studs @ 16”o.c.
- WFC engineering analysis; 666 Folsom Street project. San Francisco, CA.
- ½” wood lath & plaster, 2x4 wood studs @ 16”o.c.
- Report number WFC 01084 (ran to failure; 93 minutes)
ASTM E 119, 1 Hr Ceiling System
- 7/8” plaster over metal lath fastened to trusses @ 24”o.c. with R-30 insulation.
- WFC evaluation letter. Woodland Church project.
FOAM/FOAM COMPOSITE PANELS
UBC 26-3, Room Corner Test
- 6” semi-rigid, low density polyurethane foam.
- Report No. RAD-3321
ASTM E-84, Steiner Tunnel Test
- 1 ½” fiberglass/foam PVC acoustic panels.
- Report: (SW Laboratories) SWRI 01-6739-144a
- 2” rigid foam Co-Polymer.
- Report No: OMEGA 16941-118444
- 1.5” polyurethane modified polyisocyanurate foam
- Report Number: Dow 15824-124680
UBC 26-2, Thermal Barrier Test
- 24 gauge steel exterior skin polyurethane foam interior.
- Report No: WFC 99063
- ¼” Gypsum board skin, polyurethane foam 1/16” fiberglass skin.
- Report No: WFC 01084.T3
- 7/16” Oriented Strand Board (OSB) exterior skin, polystyrene foam interior.
- Report No: WFC 99070
ASTM E-662-97, Smoke Density Test
- ¾” Polyurethane foam filters
- Report: OMEGA 16288-108753
ASTM E-3675-98, Radiant Panel Test
- ¾” Polyurethane foam filters
- Report: OMEGA 16288-108756
ASTM E-1623, I-Cal Tests
- 2” Polyurethane foam with steel plate
- Report: WFC 98054
ASTM E 119, Polyimide Foam
- Wall panel test on SOLIMIDE TA-340 & HD-31 foam
CELLULOSE TILES
ASTM E-1623, I-Cal
- ½” cellulose ceiling tiles
FM 4975 (Hydrocarbon)
- ½” cellulose ceiling tiles
CONCRETE
ASTM E 84, Steiner Tunnel Test
- ½” Cement board.
- Omega 15810-110128
ASTM E 119, 2 Hr Ceiling System
- 2 ¾” concrete slab-floors.
- Report number WFC 01011
TIN CEILING
ASTM E 119, 1 Hr Ceiling System
- Embossed tin attached to 1”x2” wood @ 4x10 joists @ 12”o.c. with 1½” wood flooring.
- Report: 00050 T1
ASTM E 119, 2 Hr Ceiling System
- Embossed Tin over 3/8” rock board attached to nominal 3x10 joists @ 16”o.c. with ¼” wood sub-floor with suspended T-Bar ceiling.
- WFC engineering letter and Structural engineering calculations: Ron Loar, P.E. Westwood Church project.
METAL
ASTM E 119, 2 Hr Wall System
- 10 gage metal plate
- Report: WFC 99053
FIBERGLASS
ASTM E 84, Steiner Tunnel Test
- 1 ½” Fiberglass/Foam PVC acoustic panels
- Report: (SWRI 01-6739-144a
BSS-7239-88, Boeing Toxicity Test
- ¼” Fiberglass
- Report: OMEGA 15810-103929
ASTM E 1354-94, Cone Calorimeter
- ¼” fiberglass panels
- Report: OMEGA 15810-102686
ASTM E 662-97, Smoke Density Test
- 1/8” fiberglass transit panels
ASTM E 3675-98, Radiant Panel Test
- 1/8” fiberglass transit panels